AORA GT600 Reverse Osmosis Water Filter

Price: €389.00
Gross, plus shipping
The AORA GT600 is a fully filtered, tankless water filter featuring 8-stage technology, providing clean and fresh osmosis water straight from the tap.
Fitting

By buying with these payment methods you accept our terms. Terms and conditions · Right of withdrawal

Share
Rating:
(0)

The AORA GT600 is a modern reverse osmosis water filter with 8-stage filtration that can be installed without a storage tank. It delivers up to 1.57 litres per minute and combines sediment, carbon and RO membrane filters to remove contaminants such as heavy metals, microplastics and PFAS.

  • Supplier: Still
  • Colour: White
  • Connection type: Fixed water connection
  • Reverse osmosis: Yes, 8-stage technology
  • Water flow rate: up to 1.57 l/min
  • Pure water to waste water ratio: 3 : 1

The Quick-Change system allows the filter to be replaced in less than 3 seconds without the need for tools. The display automatically reminds you when the next filter change is due, and the unit has been awarded the ‘Tested Quality’ certification.

  • Reference
    11660
  • In stock
    100 Items

  • Item number
    11660
  • Output types
    Silence
  • Design type
    Under-sink
  • Colour
    White
  • Connection type
    Permanent water connection
  • Osmosis
    Yes
  • Reverse osmosis filtration
    8 steps
  • Water flow
    up to 1.57 l/min
  • Fresh water to waste water
    3 : 1
  • Quick-Change Filter Replacement
    3 sec.
  • Filtration
    8-stage reverse osmosis
  • Colour of the main unit
    White
  • Filter replacement
    Quick Change, no tools required
  • PPC filter
    Replacement interval: every 6 months
  • RO membrane
    Replacement interval: every 12–24 months
  • Installation option
    Can be installed horizontally

Safety Information_EL

Download (253.93KB)

    What is the difference between a water ioniser and a reverse osmosis system?

    A water ioniser is a device used to alter the pH level of water and to separate it into alkaline and acidic water. It uses electrolysis technology to ionise the water and produce negatively and positively charged ions. Alkaline water is often used as drinking water and is said to have an alkalising effect on the body, whilst acidic water can be used for cleaning purposes. Water ionisers aim to alkalise the water and alter its taste.

    On the other hand, a reverse osmosis system is a system based on the principle of reverse osmosis, as described previously. It uses a semi-permeable membrane to remove impurities such as salts, minerals, heavy metals, bacteria and viruses from the water. The process of reverse osmosis produces clean, filtered water that can be used for various purposes such as drinking, cooking or industrial applications. Reverse osmosis systems aim to rid the water of a wide range of contaminants and ensure high water quality.

    The main difference between a water ioniser and a reverse osmosis system lies in how they work and what they are designed to achieve. Whilst a water ioniser is primarily designed to alter the pH level of the water and provide potentially alkaline water, a reverse osmosis system focuses on removing contaminants and providing clean, filtered water. The choice between the two depends on individual requirements and preferences – whether one prefers water ionisation or comprehensive purification.




    Are you satisfied with this article? Usefulness of the article: 8 / 0

    What is reverse osmosis?

    Reverse osmosis is a water treatment process based on the principle of selective permeability. It is a widely used method for desalinating water and removing impurities. Reverse osmosis is used in various applications, including drinking water treatment, seawater desalination, wastewater treatment and process water purification.

    The basic principle of reverse osmosis involves forcing water through a semi-permeable membrane under high pressure. The membrane is designed to retain certain molecules and ions, whilst allowing water molecules to pass through. This effectively removes salts, minerals, organic compounds, heavy metals and other contaminants from the water.

    The reverse osmosis process consists of several components. First, the water to be treated is fed through a pre-filter to remove coarse impurities such as sediment, particles and rust. The water is then pumped into the reverse osmosis unit, where it flows through the semi-permeable membrane.

    The high pressure generated by a pump forces the water to pass through the membrane. The membrane consists of a thin layer of semi-permeable material capable of allowing water molecules to pass through whilst retaining larger dissolved substances. This removes most impurities from the water.

    The purified water that has passed through the membrane is known as permeate and can be used for various purposes, including drinking water, food processing or industrial processes. The water that has not passed through the membrane and contains the contaminants is known as concentrate and is usually disposed of or recirculated back into the reverse osmosis process to optimise water consumption.

    The performance of a reverse osmosis unit is influenced by various factors, including pressure, the type of membrane, the temperature of the water, and the nature and concentration of the contaminants in the feed water. To ensure the efficiency and longevity of the system, it is important to carry out regular maintenance, such as cleaning and replacing the membranes.

    Reverse osmosis offers an effective method of water treatment, particularly in areas with limited access to clean water or where high-purity water is required. It is a proven process for desalinating seawater and removing contaminants from various water sources. Continuous technological development has led to improved membranes and more efficient systems, enabling cost-effective and economical water treatment.



    Are you satisfied with this article? Usefulness of the article: 0 / 0

    What is the recommended replacement interval for the PPC filters and RO membrane?

    A six-month replacement interval is recommended for the PPC filter. The RO membrane should be replaced after 12 to 24 months.


    Are you satisfied with this article? Usefulness of the article: 0 / 0

    Can the AORA GT600 also be installed in a horizontal position?

    Yes, a flush-mounted installation is possible and can be useful in narrow spaces or behind skirting boards.


    Are you satisfied with this article? Usefulness of the article: 0 / 0

    Which tap is supplied with the AORA GT600?

    The AORA GT600 comes with a 3-way stainless steel tap featuring a quick-change function. The tap of your choice can be selected when placing your order.


    Are you satisfied with this article? Usefulness of the article: 0 / 0

    What does ‘Certified Quality’ mean for the AORA GT600?

    'Certified quality' means that the AORA GT600 has been tested by the German Institute for Consumer Protection (IfV) and certified in accordance with DVN:5750.


    Are you satisfied with this article? Usefulness of the article: 0 / 0

    What types of water are available from the tap?

    The tap provides hot, cold and filtered water directly at the sink.


    Are you satisfied with this article? Usefulness of the article: 0 / 0

Secure payment
Pay via PayPal, credit card, Klarna or bank transfer.
Terms of Delivery
Free delivery on orders of €70.00 or more | Delivery within 1–3 working days
Return Policy
14-day right of withdrawal
  • PayPal
  • Visa
  • Mastercard
  • Überweisung

Shop safely and securely

Loading...
Back to top