AURA W23 – Countertop reverse osmosis system with hydrogen ioniser and hot water function | White / Black
- 4-in-1 system: reverse osmosis water filter, hydrogen-rich water, chilled water and hot water
- Hydrogen water with PEM/SPE electrolysis technology – 2-litre H₂ flow-through tank
- 6 temperature settings: chilled, room temperature, 45 °C, 80 °C, 90 °C, 100 °C
- Child safety lock for hot water dispensing
- Instant limescale-free hot water – no need for a kettle
- 3-stage filtration: carbon filter, sediment-carbon filter & high-performance 200 GPD membrane
- LED UVC disinfection
- Touchscreen display for all functions, including filter change indicator
- Child’s play to change filters thanks to Quick-Change technology
- Elegant design in white or black
- Choice of connection type: without a fixed water connection (flexible, canister operation) or with a fixed water connection (fully automatic, continuous operation)
AURA W23 – Reverse osmosis with hydrogen ioniser & hot water
Three-stage filtration · PEM/SPE hydrogen technology · 6 temperature settings · Touchscreen
Pure water at the touch of a button
Three filtration stages plus a 200 GPD osmosis membrane remove limescale, heavy metals, chlorine and microparticles – without any complicated setup.
Integrated UVC unit
The integrated LED UVC unit continuously sterilises the water and inhibits the growth of microorganisms – ensuring the highest level of purity.
Hydrogen-rich water with PEM/SPE
The integrated hydrogen generator (2-litre flow-through tank) enriches the water with molecular hydrogen – a field of modern water research that is the subject of intensive study.
Six temperatures – one appliance
From ice-cold (10 °C) to boiling hot (100 °C): baby formula, tea, coffee or fresh drinking water – instantly at the desired temperature. No need for a kettle anymore.
No more lugging around water crates
Fresh, filtered water straight from the tap – available with or without a fixed water connection, depending on the installation situation.
Minimalist design
Touchscreen display, sleek housing in white or black – the AURA W23 blends discreetly into any modern kitchen.
What the AURA W23 offers you
- 4-in-1 system: reverse osmosis water filter, hydrogen-rich water, chilled water and hot water
- Hydrogen-rich water with PEM/SPE electrolysis technology – 2-litre H₂ flow-through tank
- 6 temperature settings: chilled (10 °C), room temperature, 45 °C, 80 °C, 90 °C, 100 °C
- Child safety lock for hot water dispensing
- Instant limescale-free hot water – no need for a kettle
- 3-stage filtration: carbon filter, sediment-carbon filter & high-performance 200 GPD membrane
- LED UVC disinfection
- Touchscreen display for all functions, including filter change indicator
- Child’s play to change filters thanks to Quick-Change technology
- Elegant design in white or black
Three-stage filtration with QuickChange technology
- PAC sediment-carbon filter – every 6 months
- CF carbon filter – every 6 months
- RO membrane – every 12–24 months
Contents of delivery
- AURA W23 tabletop reverse osmosis system with hydrogen ioniser (specification as per order)
- Filter starter set (already fitted)
- Drip tray
- German operating instructions
Technical details
| Feature | Details |
|---|---|
| Brand | AURA |
| Model | W23 |
| Version | Benchtop unit |
| Filtration method | Reverse osmosis filtration |
| Filter (internal) | 1× reverse osmosis (RO) membrane 1× Sediment and activated carbon filter (PAC) 1× carbon filter (CF) |
| Hydrogen ioniser | PEM/SPE hydrogen electrolysis |
| Sterilisation | LED-UVC |
| Temperature settings | 10 °C cold · room temperature · 45 °C · 80 °C · 90 °C · 100 °C |
| Permanent water connection | Optional (with or without) |
| Suitable water source | Tap water |
| Water filtration capacity | 30 litres/hour |
| Hot water flow rate | 18 litres per hour (≥ 90 °C) |
| Wastewater ratio | 2:1 (2 L osmosis water : 1 L waste water) |
| Display | Touchscreen |
| Rated voltage / frequency | 220 V–240 V / 50 Hz |
| Dimensions (W × H × D) | 240 × 430 × 350 mm |
| Weight | 9.6 kg (empty weight) |
| Warranty | 2 years (private customers) · 12 months (business customers) |
📄 Study: Water savings from reverse osmosis effluent in horticulture (PubMed)
You can find out more about the effects of hydrogen-rich water in our guide.
-
Assembly and disassembly: The AORA W23 is atabletop unit, which makes it easier to transport than under-sink units. However, you must dismantle it carefully to avoid damage.
-
Turn off the water supply and disconnect the system from the tap.
-
Empty the water tank completely to prevent leaks.
-
Pack the unit and all components (hoses, filters, tank) securely for transport.
-
-
Reassembly: When reassembling the system, ensure that all connections are tight and that the system is connected correctly. Check the filters and replace them if necessary.
-
Water quality at the new location: The performance of the reverse osmosis system depends on the quality of the inlet water. If the water quality differs significantly (e.g. whilst on holiday), it may be advisable to check or adjust the filters.
-
Heavy metals: lead, copper, cadmium, chromium, nickel, etc.
-
Chemical contaminants: chlorine, pesticides, herbicides, fungicides.
-
Micro-organisms: bacteria, viruses (even more effective when combined with a UV filter).
-
Salts and minerals: nitrates, sulphates, fluorides, arsenic.
-
Particles: Sediment, rust, sand, suspended solids.
-
Organic compounds: Medication residues, hormones.
-
Gases: Dissolved gases such as oxygen or carbon dioxide are not removed.
-
Very small molecules: Some extremely small organic molecules can pass through the membrane.
-
Taste and smell: Chlorine and other substances that affect the taste are removed, but the taste of pure water may be perceived as ‘flat’ due to the absence of minerals.
-
Reverse osmosis also removeshealthy mineralssuch as calcium and magnesium. However, some models (including, where applicable, the AORA W23) have amineralisation filter which reintroduces important minerals into the water after filtration.
A water ioniser is a device used to alter the pH level of water and to separate it into alkaline and acidic water. It uses electrolysis technology to ionise the water and produce negatively and positively charged ions. Alkaline water is often used as drinking water and is said to have an alkalising effect on the body, whilst acidic water can be used for cleaning purposes. Water ionisers aim to alkalise the water and alter its taste.
On the other hand, a reverse osmosis system is a system based on the principle of reverse osmosis, as described previously. It uses a semi-permeable membrane to remove impurities such as salts, minerals, heavy metals, bacteria and viruses from the water. The process of reverse osmosis produces clean, filtered water that can be used for various purposes such as drinking, cooking or industrial applications. Reverse osmosis systems aim to rid the water of a wide range of contaminants and ensure high water quality.
The main difference between a water ioniser and a reverse osmosis system lies in how they work and what they are designed to achieve. Whilst a water ioniser is primarily designed to alter the pH level of the water and provide potentially alkaline water, a reverse osmosis system focuses on removing contaminants and providing clean, filtered water. The choice between the two depends on individual requirements and preferences – whether one prefers water ionisation or comprehensive purification.
Reverse osmosis is a water treatment process based on the principle of selective permeability. It is a widely used method for desalinating water and removing impurities. Reverse osmosis is used in various applications, including drinking water treatment, seawater desalination, wastewater treatment and process water purification.
The basic principle of reverse osmosis involves forcing water through a semi-permeable membrane under high pressure. The membrane is designed to retain certain molecules and ions, whilst allowing water molecules to pass through. This effectively removes salts, minerals, organic compounds, heavy metals and other contaminants from the water.
The reverse osmosis process consists of several components. First, the water to be treated is fed through a pre-filter to remove coarse impurities such as sediment, particles and rust. The water is then pumped into the reverse osmosis unit, where it flows through the semi-permeable membrane.
The high pressure generated by a pump forces the water to pass through the membrane. The membrane consists of a thin layer of semi-permeable material capable of allowing water molecules to pass through whilst retaining larger dissolved substances. This removes most impurities from the water.
The purified water that has passed through the membrane is known as permeate and can be used for various purposes, including drinking water, food processing or industrial processes. The water that has not passed through the membrane and contains the contaminants is known as concentrate and is usually disposed of or recirculated back into the reverse osmosis process to optimise water consumption.
The performance of a reverse osmosis unit is influenced by various factors, including pressure, the type of membrane, the temperature of the water, and the nature and concentration of the contaminants in the feed water. To ensure the efficiency and longevity of the system, it is important to carry out regular maintenance, such as cleaning and replacing the membranes.
Reverse osmosis offers an effective method of water treatment, particularly in areas with limited access to clean water or where high-purity water is required. It is a proven process for desalinating seawater and removing contaminants from various water sources. Continuous technological development has led to improved membranes and more efficient systems, enabling cost-effective and economical water treatment.
It may be necessary to clean the float during cleaning to prevent any algae from forming in the water tank.
Please always ensure the float is returned to the correct position when reassembling the unit. In other words, the magnet must face towards the appliance to reactivate the pump signal. This should resolve the issue in most cases.

Yes, theAORA W23 reverse osmosis systemis, in principle, portable and can be moved to a new location. Here are the key points you should bear in mind:
TheAORA W23is a reverse osmosis system that is particularly effective at removing contaminants from water. Here is an overview:
What is filtered out?
What is not filtered out?
Note on minerals:
The installation of our reverse osmosis systems (such as the W12 or W23) can be carried out by anyone with some DIY experience, using the connection materials supplied and the illustrated installation instructions. The system is usually connected to the cold water supply under the sink and to a mains power supply. If you are unsure, we recommend having the installation carried out by a qualified plumber. Our customer service team will be happy to assist you with any questions regarding installation by telephone or email.
Pay via PayPal, credit card, Klarna or bank transfer.
Free delivery on orders of €70.00 or more | Delivery within 1–3 working days
14-day right of withdrawal
Shop safely and securely
You might also like
Product video: AURA W23 Osmoseanlage: Wasserstoffgenerator und Temperaturkontrolle
Product Reviews / Q&A
-
Reviews (1)
-
Questions & Answers (0)
-
Latest
-
Latest