SPRUDELUX PRO TOUCH – Reverse osmosis system with sparkling water and hot water
The SPRUDELUX PRO TOUCH is a comprehensive solution for your drinking water needs. With 8 water programmes, a 7-inch touchscreen control panel and integrated UV sterilisation, the unit combines state-of-the-art technology in a compact design. Filtration technology – 4-stage + UV sterilisation – removes heavy metals, germs and odours. A 5-litre tank or fixed water connection allows for flexible installation. Sparkling water and hot water are ready for use in just 3 seconds.
- Technical specifications: 4-stage filtration, 2200 W heating power, 18 L/h hot water, 8 programme temperatures
- Installation: 5-litre tank or mains water connection, 7-inch touchscreen, Wi-Fi capable
- Maintenance: Hot water ready in 3 seconds, filter replacement every 12 months
- Contents: Reverse osmosis system, filter cards, 5-litre tank, sparkling water storage tank
-
Reference20884
-
In stock100 Items
-
Item number20884
-
Output typesStill, chilled still, soda or hot water
-
Design typeTable top
-
ColourBlack or silver
-
Connection typePermanent water connection or tank
-
OsmosisYes
-
RO membrane0.0001 microns
-
Rated heat output2200 W (during heating)
-
Rated cooling capacity120 W (during cooling)
-
Hot water capacity18 L/h (≥90 °C)
-
Cold water capacity8 L/h (4–8 °C)
-
Hot water supply3 seconds
-
Filtration technology4-stage + UV sterilisation
-
Filter cartridgePP + activated carbon + 200G RO + T33
-
Filter replacement interval12 months / 3,000 litres
-
Water tank capacity5 L
-
Water flow rate520 ml/min
-
Water treatment capacity2,000 litres in total
-
Dimensions (D × W × H)467 × 220 × 430 mm
-
Net weight20 kg
-
Display7-inch touchscreen
-
Rated voltage220 V AC · 50 Hz
-
Total rated power2250 W
-
Working pressure0.4–0.6 MPa (4–6 bar)
-
Water temperature (inlet)5–38 °C
-
Operating temperature (ambient)5–38 °C
-
Product modelW60 / S-2025
-
UVUV sterilisation: kills any remaining bacteria and viruses after filtration. Can be activated via the touchscreen.
-
Temperature ranges4°–8°, 45°, 50°, 60°, 70°, 80°, 85°, 95° C
-
Casing materialABS
- TFC membrane (thin film composite, made of polyamide): fitted in most household systems today. It holds back dissolved substances very extensively but is sensitive to chlorine. That is why an activated carbon pre-filter sits in front of it.
- CTA membrane (cellulose triacetate): it tolerates chlorine better, but holds back fewer dissolved substances and only works within a narrower pH range. It is rarely found in new household devices.
- Output: usually stated in GPD (gallons per day), it tells you how much filtered water is produced in a given time. It says nothing about filter quality.
- Design: replacement membranes only fit the housing and connections of the device they are made for. That is why the AORA GT600, the AORA GT800 and the W23 each have their own replacement membranes. A membrane from another device will usually not fit.
- Replacement interval: it depends on the local water quality and the amount used. On the W19 and the W23, the RO membrane should be replaced after 12 to 24 months. On the AORA GT800, we recommend replacing the membrane after about 18 months and the PPC pre-filter every 6 months.
A water ioniser is a device that changes the pH value of water and separates it into alkaline and acidic water. It does this by electrolysis: an electric current produces negatively and positively charged ions. The alkaline water is used as drinking water, the acidic water for cleaning. A water ioniser therefore mainly changes the pH value and the taste of the water.
A reverse osmosis system, by contrast, works on the principle of reverse osmosis. It forces the water through a semi-permeable membrane that holds back impurities such as salts, minerals, heavy metals, bacteria and viruses. The filtered water can be used for drinking, cooking or technical applications. A reverse osmosis system aims to remove as many substances from the water as possible.
The main difference is therefore the purpose: a water ioniser changes the pH value, a reverse osmosis system purifies the water thoroughly. Which device suits you depends on what matters more to you.
Osmosis membranes: how do they differ?
The heart of every reverse osmosis system is the membrane. In household systems you will mainly come across two types:
Beyond that, membranes differ in three respects:
Can an ioniser and reverse osmosis be combined?
Yes, the two methods are not mutually exclusive. An ioniser can be connected after a reverse osmosis system. There are also reverse osmosis devices with a built-in additional module, for example the W23 with hydrogen generator. If your main aim is to remove substances from tap water, reverse osmosis is what counts. If you care about pH value or taste, the ioniser is what counts.
Reverse osmosis is a water treatment process based on the principle of selective permeability. It is a widely used method for desalinating water and removing impurities. Reverse osmosis is used in various applications, including drinking water treatment, seawater desalination, wastewater treatment and process water purification.
The basic principle of reverse osmosis involves forcing water through a semi-permeable membrane under high pressure. The membrane is designed to retain certain molecules and ions, whilst allowing water molecules to pass through. This effectively removes salts, minerals, organic compounds, heavy metals and other contaminants from the water.
The reverse osmosis process consists of several components. First, the water to be treated is fed through a pre-filter to remove coarse impurities such as sediment, particles and rust. The water is then pumped into the reverse osmosis unit, where it flows through the semi-permeable membrane.
The high pressure generated by a pump forces the water to pass through the membrane. The membrane consists of a thin layer of semi-permeable material capable of allowing water molecules to pass through whilst retaining larger dissolved substances. This removes most impurities from the water.
The purified water that has passed through the membrane is known as permeate and can be used for various purposes, including drinking water, food processing or industrial processes. The water that has not passed through the membrane and contains the contaminants is known as concentrate and is usually disposed of or recirculated back into the reverse osmosis process to optimise water consumption.
The performance of a reverse osmosis unit is influenced by various factors, including pressure, the type of membrane, the temperature of the water, and the nature and concentration of the contaminants in the feed water. To ensure the efficiency and longevity of the system, it is important to carry out regular maintenance, such as cleaning and replacing the membranes.
Reverse osmosis offers an effective method of water treatment, particularly in areas with limited access to clean water or where high-purity water is required. It is a proven process for desalinating seawater and removing contaminants from various water sources. Continuous technological development has led to improved membranes and more efficient systems, enabling cost-effective and economical water treatment.
Pay via PayPal, credit card, Klarna or bank transfer.
Free delivery on orders of €70.00 or more | Delivery within 1–3 working days
Made-to-order items up to 14 days delivery time
14-day right of withdrawal
Shop safely and securely